Use a reset to clear a latch after the cause is gone. Stop when the same fault comes back. A latch is the inverter remembering a fault and refusing to run until that memory is cleared. Emptying the memory leaves a failed fan failed, a ground fault still leaking, and a wrong setting still wrong. The button is not a repair.
What you may clear
After a grid event that has ended, some inverters stay stopped until a person or a timer clears the latch. The manual is what says a reset is allowed for that code. Write the code, the time, and a photograph of the screen before you clear anything. One informed attempt, after the cause has passed, tells you whether the latch was the whole story. The button names live in that unit's manual. This page will not print a sequence. A combination copied from another brand is how settings disappear.
If the reset on offer is "restore defaults," stop and open what to photograph before inverter settings change. Factory charge voltages are a battery problem wearing a troubleshooting costume. Capture the grid code in the same photos. You will want both if the screens come back unfamiliar.
What the button cannot replace
A fan that scrapes or a smell of hot insulation is still there after the display goes quiet. Inverter noise says which sounds track load and which sounds mean stop. A ground-fault light means a path the design did not want. What a PV ground fault means says to quit cycling it. An arc-fault trip means the DC conductors need a qualified look, including the trip you hoped was a nuisance. Arc-fault protection is that page. Resetting either alarm deletes the clue and leaves the defect.
Wrong charge voltages, a wrong battery type, and a wrong grid profile survive every latch clear. They are settings. They change when someone changes them, not when the fault memory is emptied. If production is simply low because of cloud, there may be no fault to reset. Check the sky and the alarm list before you touch the button and call it maintenance.
When the same code returns
If the same code returns, the cause is still present. Further resets count how often the button was pressed. Stop. Give the photos, the times, and the weather notes to a qualified person. A pattern of returns belongs with signs a solar inverter is failing, after that person has the code, not before. Do not defeat the protection that raised the code in order to keep the kilowatt-hours flowing.
Shut the unit down by the labels posted on it, or leave it in the fault state it chose. When isolation is required, the AC and DC disconnects are the handles the design provided. What they separate is in AC and DC disconnects for solar. Routine inverter maintenance is the visit that happens when nothing is latched: vents, labels, and the production log. A reset loop is not that visit.
Keep a one-line log: date, code, weather, and whether the code returned. Repeated returns are one cause with a counter, not a series of fresh glitches. The log is what a later warranty conversation asks for, and it is useless if every reset wiped the screen before the photo. If you are unsure the cause has passed, skip the attempt. Waiting for a qualified person leaves the evidence on the screen.