Apartment solar
Microinverters Solutions for Balcony
A balcony system is one or two modules, a microinverter, and a cable into the apartment. Daytime loads use that power first. Surplus goes out through the meter. If the grid drops, the inverter stops.
Use it when the roof is not yours
- The array is one or two modules on a railing, a stand, or a wall you are allowed to fix to.
- The daytime base load is small: a fridge, a router, a laptop. A balcony rarely covers cooking.
- The destination allows a plug-in generator, and the socket is a fixed wall outlet on its own circuit.
Skip it when the job is a house roof
- You need backup in a blackout. A grid-tied microinverter shuts off when the grid does.
- The module current is above the inverter input, or the cold open-circuit voltage is above 60 V.
- The building is 120 V split-phase. These inverters are 220–240 V.
Where the power goes
One module is often the right size when the apartment’s daytime load sits well under 100 W. The second module mostly exports, and export from a plug-in system is often unpaid.
Two modules need two DC inputs, or one dual-input inverter. Each module still has its own tracker. The AC cable still ends in one fixed socket, never a multi-socket adaptor.
A grid-tied microinverter needs the grid in order to run. In an outage the balcony goes dark with the rest of the apartment. Backup is a different product.
Which inverter fits a balcony
ShineTong microinverters are 220–240 V, 60 V DC maximum, IP67. Matching the voltage number is not a grid approval. The destination still has to accept the unit.
| Unit | Balcony use |
|---|---|
| ST-500M, 500 or 600 W | One module. Input current stops at 14 A, so a high-current module may not fit. Ambient to 65°C. |
| ST-1200D, 800 W SKU | Two inputs. Only the 800 W rating sits under an 800 VA cap. The 1600 W rating does not. |
| ST-2800Q, 2000–2800 W | Four modules on a roof trunk. Too large for a plug-in balcony. |
The product table lists a 25-year warranty and MPPT above 99.5% on the ST-500M, above 99.8% on the other two. Published maximum CEC efficiency of 97.5% is the ST-2800Q figure only.
Germany is a special case
A layperson plug-in system there is capped at 800 VA on the inverter. A household socket is only in play when module power is within 960 W and the plug standard for that path is met. Above that, the job needs the permitted energy plug or an electrician. Other countries do not inherit 800 VA.
A module is about 1.8 by 1.0 m and about 20 kg. Cable ties are not a mount. The sizing guide walks through the same limits: what size solar balcony system.
Send the module sheet
Country, module count, Imp and Isc, and cold Voc. We will say whether the ST-500M or an 800 W ST-1200D can take that module, and we will not treat 220–240 V as a certificate.