Apartment solar

Microinverters Solutions for Balcony

A balcony system is one or two modules, a microinverter, and a cable into the apartment. Daytime loads use that power first. Surplus goes out through the meter. If the grid drops, the inverter stops.

Solar modules on a railing

Use it when the roof is not yours

  • The array is one or two modules on a railing, a stand, or a wall you are allowed to fix to.
  • The daytime base load is small: a fridge, a router, a laptop. A balcony rarely covers cooking.
  • The destination allows a plug-in generator, and the socket is a fixed wall outlet on its own circuit.

Skip it when the job is a house roof

  • You need backup in a blackout. A grid-tied microinverter shuts off when the grid does.
  • The module current is above the inverter input, or the cold open-circuit voltage is above 60 V.
  • The building is 120 V split-phase. These inverters are 220–240 V.

Where the power goes

Module A Module B Microinverter DC in, 220–240 V out Apartment loads Fridge, router, lights Used here first Meter Surplus only Stopped

Two modules need two DC inputs, or one dual-input inverter. Each module still has its own tracker. The AC cable still ends in one fixed socket, never a multi-socket adaptor.

Which inverter fits a balcony

ShineTong microinverters are 220–240 V, 60 V DC maximum, IP67. Matching the voltage number is not a grid approval. The destination still has to accept the unit.

UnitBalcony use
ST-500M, 500 or 600 WOne module. Input current stops at 14 A, so a high-current module may not fit. Ambient to 65°C.
ST-1200D, 800 W SKUTwo inputs. Only the 800 W rating sits under an 800 VA cap. The 1600 W rating does not.
ST-2800Q, 2000–2800 WFour modules on a roof trunk. Too large for a plug-in balcony.

The product table lists a 25-year warranty and MPPT above 99.5% on the ST-500M, above 99.8% on the other two. Published maximum CEC efficiency of 97.5% is the ST-2800Q figure only.

Germany is a special case

A layperson plug-in system there is capped at 800 VA on the inverter. A household socket is only in play when module power is within 960 W and the plug standard for that path is met. Above that, the job needs the permitted energy plug or an electrician. Other countries do not inherit 800 VA.

A module is about 1.8 by 1.0 m and about 20 kg. Cable ties are not a mount. The sizing guide walks through the same limits: what size solar balcony system.

Send the module sheet

Country, module count, Imp and Isc, and cold Voc. We will say whether the ST-500M or an 800 W ST-1200D can take that module, and we will not treat 220–240 V as a certificate.

Ask about a balcony kit